Roof pitched for rainwater discharge in to plastic guttering and down pipes to grade level. Down pipe cloaked to discourage climbing
Main cable entry via apertures in the module wall fitted with vertical bolt on mild steel gland plates
Personnel access doors fitted with stainless steel hinges, locks, high performance weather seals and a panic bar for emergency exit. A door contact will be fitted wired to an alarm junction box. All external fixings to be stainless steel, anti vandal
High level 50 x 6mm un insulated plain copper earth bar around the full internal perimeter of the module with droppers down 2 off through the wall earth bosses welded to housing structure, and bolted disconnect links at low level. All joints (except bolted joints) to be brazed. Earth bar to be locally tinned at specified positions where cable joints are to be made
Overhead cable management / ladder rack fabricated in to the module ceiling
Ventilation system or HVAC
Standards & Regulations
Supply, install and testing of Domestic electrical services. The above to be installed and tested in accordance with the latest edition of the IEE Regulations
Full documentation package including mechanical and electrical build drawings, maintenance manual, test certificate for Bradgate installed scope